368 research outputs found

    DARE: evaluating Data Accuracy using node REputation

    Get PDF
    Typical wireless sensor networks (WSNs) applications are characterized by a certain number of different requirements such as: data accuracy, localization, reputation, security, and confidentiality. Moreover, being often battery powered, WSNs face the challenge of ensuring privacy and security despite power consumption limitations. When the application scenario allows their use, data aggregation techniques can significantly reduce the amount of data exchanged over the wireless link at the price of an increased computational complexity and the potential exposition to data integrity risks in the presence of malicious nodes. In this paper, we propose DARE, an hybrid architecture combining WSNs with the wireless mesh networking paradigm in order to provide secure data aggregation and node reputation in WSNs. Finally, the use of a secure verifiable multilateration technique allows the network to retain the trustworthiness of aggregated data even in the presence of malicious node. Extensive performance evaluations carried out using simulations as well as a real-world prototype implementation, show that DARE can effectively reduce the amount of data exchanged over the wireless medium delivering up to 50% battery lifetime improvement to the wireless sensors

    Security Games for Node Localization through Verifiable Multilateration

    Get PDF
    Most applications of wireless sensor networks (WSNs) rely on data about the positions of sensor nodes, which are not necessarily known beforehand. Several localization approaches have been proposed but most of them omit to consider that WSNs could be deployed in adversarial settings, where hostile nodes under the control of an attacker coexist with faithful ones. Verifiable multilateration (VM) was proposed to cope with this problem by leveraging on a set of trusted landmark nodes that act as verifiers. Although VM is able to recognize reliable localization measures, it allows for regions of undecided positions that can amount to the 40 percent of the monitored area. We studied the properties of VM as a noncooperative two-player game where the first player employs a number of verifiers to do VM computations and the second player controls a malicious node. The verifiers aim at securely localizing malicious nodes, while malicious nodes strive to masquerade as unknown and to pretend false positions. Thanks to game theory, the potentialities of VM are analyzed with the aim of improving the defender's strategy. We found that the best placement for verifiers is an equilateral triangle with edge equal to the power range R, and maximum deception in the undecided region is approximately 0.27R. Moreover, we characterized-in terms of the probability of choosing an unknown node to examine further-the strategies of the players

    Making GDPR Usable: A Model to Support Usability Evaluations of Privacy

    Full text link
    We introduce a new model for evaluating privacy that builds on the criteria proposed by the EuroPriSe certification scheme by adding usability criteria. Our model is visually represented through a cube, called Usable Privacy Cube (or UP Cube), where each of its three axes of variability captures, respectively: rights of the data subjects, privacy principles, and usable privacy criteria. We slightly reorganize the criteria of EuroPriSe to fit with the UP Cube model, i.e., we show how EuroPriSe can be viewed as a combination of only rights and principles, forming the two axes at the basis of our UP Cube. In this way we also want to bring out two perspectives on privacy: that of the data subjects and, respectively, that of the controllers/processors. We define usable privacy criteria based on usability goals that we have extracted from the whole text of the General Data Protection Regulation. The criteria are designed to produce measurements of the level of usability with which the goals are reached. Precisely, we measure effectiveness, efficiency, and satisfaction, considering both the objective and the perceived usability outcomes, producing measures of accuracy and completeness, of resource utilization (e.g., time, effort, financial), and measures resulting from satisfaction scales. In the long run, the UP Cube is meant to be the model behind a new certification methodology capable of evaluating the usability of privacy, to the benefit of common users. For industries, considering also the usability of privacy would allow for greater business differentiation, beyond GDPR compliance.Comment: 41 pages, 2 figures, 1 table, and appendixe

    Feasibility of real-time three-dimensional stress echocardiography: pharmacological and semi-supine exercise

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Real time three dimensional (RT3D) echocardiography is an accurate and reproducible method for assessing left ventricular shape and function.</p> <p>Aim</p> <p>assess the feasibility and reproducibility of RT3D stress echocardiography (SE) (exercise and pharmacological) in the evaluation of left ventricular function compared to 2D.</p> <p>Methods and results</p> <p>One hundred eleven patients with known or suspected coronary artery disease underwent 2D and RT3DSE. The agreement in WMSI, EDV, ESV measurements was made off-line.</p> <p>The feasibility of RT-3DSE was 67%. The inter-observer variability for WMSI by RT3D echo was higher during exercise and with suboptimal quality images (good: k = 0.88; bad: k = 0.69); and with high heart rate both for pharmacological (HR < 100 bpm, k = 0.83; HR ≥ 100 bpm, k = 0.49) and exercise SE (HR < 120 bpm, k = 0.88; HR ≥ 120 bpm, k = 0.78). The RT3D reproducibility was high for ESV volumes (0.3 ± 14 ml; CI 95%: -27 to 27 ml; p = n.s.).</p> <p>Conclusions</p> <p>RT3DSE is more vulnerable than 2D due to tachycardia, signal quality, patient decubitus and suboptimal resting image quality, making exercise RT3DSE less attractive than pharmacological stress.</p

    Incremental value of contrast myocardial perfusion to detect intermediate versus severe coronary artery stenosis during stress-echocardiography

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>We aimed to compare the incremental value of contrast myocardial perfusion imaging (MPI) for the detection of intermediate versus severe coronary artery stenosis during dipyridamole-atropine echocardiography (DASE).</p> <p>Wall motion (WM) assessment during stress-echocardiography demonstrates suboptimal sensitivity to detect coronary artery disease (CAD), particularly in patients with isolated intermediate (50%-70%) coronary stenosis.</p> <p>Methods</p> <p>We performed DASE with MPI in 150 patients with a suspected chest pain syndrome who were given clinical indication to coronary angiography.</p> <p>Results and discussion</p> <p>When CAD was defined as the presence of a ≥50% stenosis, the addition of MPI increased sensitivity (+30%) and decreased specificity (-14%), with a final increase in total diagnostic accuracy (+16%, p < 0.001). The addition of MPI data substantially increased the sensitivity to detect patients with isolated intermediate stenosis from 37% to 98% (p < 0.001); the incremental sensitivity was much lower in patients with severe stenosis, from 85% to 96% (p < 0.05), at the expense of a higher decrease in specificity and a final decrease in total diagnostic accuracy (-18%, p < 0.001).</p> <p>Conclusions</p> <p>The addition of MPI on top of WM analysis during DASE increases the diagnostic sensitivity to detect obstructive CAD, whatever its definition (≥50% or > 70% stenosis), but it is mainly driven by the sensitivity increase in the intermediate group (50%-70% stenosis).</p> <p>The total diagnostic accuracy increased only when defining CAD as ≥50% stenosis, since in patients with severe stenosis (> 70%) the decrease in specificity is not counterbalanced by the minor sensitivity increase.</p

    Hepatocyte Growth Factor Enhances Engraftment and Function of Nonhuman Primate Islets

    Get PDF
    OBJECTIVE—Adenoviral delivery of hepatocyte growth factor (HGF) to rodent islets improves islet graft survival and function, markedly reducing the number of islets required to achieve glucose control. Here, we asked whether these prior observations in rodent models extend to nonhuman primate (NHP) islets

    Mutant p53 improves cancer cells\u2019 resistance to endoplasmic reticulum stress by sustaining activation of the UPR regulator ATF6

    Get PDF
    Missense mutations in the TP53 gene are frequent in human cancers, giving rise to mutant p53 proteins that can acquire oncogenic properties. Gain of function mutant p53 proteins can enhance tumour aggressiveness by promoting cell invasion, metastasis and chemoresistance. Accumulating evidences indicate that mutant p53 proteins can also modulate cell homeostatic processes, suggesting that missense p53 mutation may increase resistance of tumour cells to intrinsic and extrinsic cancer-related stress conditions, thus offering a selective advantage. Here we provide evidence that mutant p53 proteins can modulate the Unfolded Protein Response (UPR) to increase cell survival upon Endoplasmic Reticulum (ER) stress, a condition to which cancer cells are exposed during tumour formation and progression, as well as during therapy. Mechanistically, this action of mutant p53 is due to enhanced activation of the pro-survival UPR effector ATF6, coordinated with inhibition of the pro-apoptotic UPR effectors JNK and CHOP. In a triple-negative breast cancer cell model with missense TP53 mutation, we found that ATF6 activity is necessary for viability and invasion phenotypes. Together, these findings suggest that ATF6 inhibitors might be combined with mutant p53-targeting drugs to specifically sensitise cancer cells to endogenous or chemotherapy-induced ER stress

    Indications for cardiovascular magnetic resonance in children with congenital and acquired heart disease: an expert consensus paper of the Imaging Working Group of the AEPC and the Cardiovascular Magnetic Resonance Section of the EACVI

    Get PDF
    This article provides expert opinion on the use of cardiovascular magnetic resonance (CMR) in young patients with congenital heart disease (CHD) and in specific clinical situations. As peculiar challenges apply to imaging children, paediatric aspects are repeatedly discussed. The first section of the paper addresses settings and techniques, including the basic sequences used in paediatric CMR, safety, and sedation. In the second section, the indication, application, and clinical relevance of CMR in the most frequent CHD are discussed in detail. In the current era of multimodality imaging, the strengths of CMR are compared with other imaging modalities. At the end of each chapter, a brief summary with expert consensus key points is provided. The recommendations provided are strongly clinically oriented. The paper addresses not only imagers performing CMR, but also clinical cardiologists who want to know which information can be obtained by CMR and how to integrate it in clinical decision-makin

    Perioperative risk stratification in non cardiac surgery: role of pharmacological stress echocardiography

    Get PDF
    Perioperative ischemia is a frequent event in patients undergoing major non-cardiac vascular or general surgery. This is in agreement with clinical, pathophysiological, and epidemiological evidence and constitutes an additional diagnostic therapeutic factor in the assessment of these patients. Form a clinical standpoint, it is well known that multidistrict disease, especially at the coronary level, is a severe aggravation of the operative risk. From a pathophysiological point of view, however, surgery creates conditions able to unmask coronary artery disease. Prolonged hypotension, hemorrhages, and haemodynamic stresses caused by aortic clamping and unclamping during major vascular surgery are the most relevant factors endangering the coronary circulation with critical stenoses. From the epidemiological standpoint, coronary disease is known to be the leading cause of perioperative mortality and morbidity following vascular and general surgery: The diagnostic therapeutic corollary of these considerations is that coronary artery disease – and therefore the perioperative risk – in these patients has to be identified in an effective way preoperatively
    • …
    corecore